Driver: Do you do reefer repairs on Carrier units?
Dispatch: Yes, we handle reefer repairs on both Carrier and Thermo King units. What kind of issue are you having with it?
Driver: It's giving us a sensor code and shutting down when we turn it on.
Dispatch: What is the exact code number showing on the screen? Check the display so we can narrow down what's triggering the shutdown.
Driver: The code is 100121 and the unit is currently shut down.
Dispatch: That code indicates a temperature sensor issue. It could be a faulty sensor or low refrigerant causing improper readings. The reefer shuts down automatically to protect the unit from damage.
Real calls to the 24/7 dispatch line behind this directory, shortened. Names, companies, phone numbers and exact locations are removed.
Driver: I have a 20-foot Thermo King container reefer unit that isn't staying cold. Can someone come out and look at it?
Dispatch: Does the controller show any alarm or error codes?
Driver: No, there are no codes. It's loaded with product and just isn't cooling down when we set the temperature.
Dispatch: If it's running without codes but not cooling, it may be low on Freon or have a refrigeration system issue. A technician will need to check the pressures and system.
Read the whole call →Driver: My reefer keeps giving me an alarm and shutting down after running for about five minutes.
Dispatch: Are you seeing any fault codes on the display board when it shuts down? Knowing the specific alarm code helps us diagnose what's triggering the shutdown.
Driver: I don't have the code right now, but it's a Carrier unit and the trailer is loaded.
Dispatch: We can definitely help with a Carrier reefer unit. Where are you currently located so we can get a technician rolling?
Read the whole call →Driver: Do you provide roadside repair service for Carrier reefer units near the Middleview, Virginia area?
Dispatch: Yes, we handle roadside reefer repairs in that area and we're located about 15 miles away.
Driver: Our empty Carrier reefer is running intermittently with a yellow warning light and a cylinder fault code. What could be causing that?
Dispatch: Based on those symptoms and the fault code, it's typically a faulty camshaft sensor that needs replacement.
Read the whole call →Driver: My driver has a Carrier reefer displaying a check refrigeration alarm. It turns on, runs for 10 minutes, and shuts off. Do you service reefer units?
Dispatch: Yes. When a Carrier unit shuts down after running briefly, it usually does so to protect the compressor from damage caused by low Freon or a leak. We'll need to inspect it at our shop to diagnose the exact issue.
Driver: If it is low on Freon, does that mean there is a leak somewhere in the unit?
Dispatch: Usually, yes. Loss of Freon typically means there's a leak that must be found and fixed. We'll also check the temperature sensors, but a full inspection will pinpoint the exact cause.
Read the whole call →